Fault Information


Fault Code Description
Fault Code Conditions
Fault Time Condition
Valvetronic, actuator motor: plausibility
Service Plan

VVL-System Current Too High
Fault Impact
none
Terminal 15 ON

the VVT motor current draw remains excessive over a defined period, the precise definition of this period varying according to the degree of excess current draw.

Warnings
Service Notes
1. Check supply wire to VVT motor/control module and inspect plug.
2. Replacement of VVT motor.
3. Check software version and replace DME control unit as required if the fault is entered again despite deletion of stored fault codes.