Fault Information


Fault Code Description
Fault Code Conditions
Fault Time Condition
Valvetronic, actuator motor: power supply
Service Plan

VVL-Control Motor Supply Voltage Circuit Low (Bank 1)
Fault Impact
Electrical system voltage terminal 87 >10.0 V
Terminal 15 ON

VVT servo motor power supply monitor

Warnings
Service Notes
1. Check VVT power supply voltage with multimeter. Supply voltage must lie between 5.75V and 17V.
2. If result is outside specified range: Inspect the power-supply wire to the VVT pins and check the plug.
3. If contact is stretched or corroded: Replace plug 4. If wiring harness is defective: Replace wiring harness.