Fault Code Description |
---|
Fault Code Conditions |
---|
Fault Time Condition |
---|
Valvetronic, actuator motor: power supply |
Service Plan |
---|
VVL-Control Motor Supply Voltage Circuit Low (Bank 1) |
Fault Impact |
---|
Electrical system voltage terminal 87 >10.0 V Terminal 15 ON VVT servo motor power supply monitor |
Warnings |
---|
Service Notes |
---|
1. Check VVT power supply voltage with multimeter. Supply voltage must lie between 5.75V and 17V. 2. If result is outside specified range: Inspect the power-supply wire to the VVT pins and check the plug. 3. If contact is stretched or corroded: Replace plug 4. If wiring harness is defective: Replace wiring harness. |