Fault Information


Fault Code Description
Fault Code Conditions
Fault Time Condition
DME: Oxygen sensor heating before catalytic converter 2, function
Service Plan

O2 Sensor Temperature Measurement Operating Temperature not Reached (Bank 2 Sensor 1)
Fault Impact
none
Terminal 15, engine on

Check oxygen sensor heater; oxygen sensor too cold, no fault codes logged in fault memory

Warnings
Service Notes
1. Visual inspection of wires, DME plug and O2 sensor for damage
2. Check wires (including resistance)
3. Check plug-in connections DME <=> Wiring harness <=> Upstream (pre-cat) O2 sensor for Bank 2 (water or corrosion in the plug? => Repeatedly disconnect the plug and then FIRMLY press it back in)
4. Replace O2 sensor
5. Replace DME