Fault Information


Fault Code Description
The diagnosis system monitors the DME for internal malfunctions.
Fault monitoring conditions:
The fault is detected by means of complex diagnoses in the DME.
Fault Code Conditions
General Conditions Temperature precondition:
- None
Time precondition:
- None
Other preconditions:
- Engine running.
Control unit voltage: 9 V to 16 V.
Terminal Condition Terminal 15
on
Driving Conditions
Fault Time Condition
The fault is entered within 10 seconds.
Service Plan
Check lines and plug connections between the following components:
- DME.
- Rail pressure sensor.
Replace rail pressure sensor.
Replace DME.
Fault Impact
- The engine operates in its emergency program.
Warnings
Warning Lights Malfunction indicator lamp and Check Control message
Control Center Messages
Service Notes
- None.