Fault Code Description |
---|
The diagnosis system monitors the DME for internal malfunctions. Fault monitoring conditions: The fault is detected by means of complex diagnoses in the DME. |
Fault Code Conditions | |
---|---|
General Conditions |
Temperature precondition: - None Time precondition: - None Other preconditions: - Engine running. Control unit voltage: 9 V to 16 V. |
Terminal Condition |
Terminal 15 on |
Driving Conditions |
Fault Time Condition |
---|
The fault is entered within 10 seconds. |
Service Plan |
---|
Check lines and plug connections between the following components: - DME. - Rail pressure sensor. Replace rail pressure sensor. Replace DME. |
Fault Impact |
---|
- The engine operates in its emergency program. |
Warnings | |
---|---|
Warning Lights |
Malfunction indicator lamp and Check Control message |
Control Center Messages |
Service Notes |
---|
- None. |