Fault Information


Fault Code Description
The diagnosis monitors the line for the voltage supply to the following terminals:
- Individual Digital Motor Electronics main relay: Terminal 87_2 or terminal 15N_2
- Integrated supply module: Terminal 87_2 or terminal 15N_1
Fault monitoring conditions:
The fault is detected when no voltage is applied at the DME input despite the main Digital Motor Electronics main relay being switched on.
Fault Code Conditions
General Conditions Temperature precondition:
- None
Time precondition:
- None
Other preconditions:
- None
Control unit voltage: 9 V to 16 V.
Terminal Condition Terminal 15
on
Driving Conditions
Fault Time Condition
60 ms
Service Plan
Check lines and plug connections between the following components:
- Engine control unit and Digital Motor Electronics main relay or integrated supply module
Check voltage supply
Check Digital Motor Electronics main relay and integrated supply module.
Fault Impact
- This malfunction can cause a roadside breakdown.
Warnings
Warning Lights Malfunction indicator lamp and Check Control message
Control Center Messages
Service Notes
- None.